{"id":40820,"date":"2021-11-25T13:15:20","date_gmt":"2021-11-25T13:15:20","guid":{"rendered":"https:\/\/venfilter.es\/normativa\/normativa-en7792012\/"},"modified":"2026-02-20T10:00:27","modified_gmt":"2026-02-20T09:00:27","slug":"norma-en7792012","status":"publish","type":"normativa","link":"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/","title":{"rendered":"Norma EN779:2012"},"content":{"rendered":"<p>Filtros de Ar de Ventila\u00e7\u00e3o Geral para a elimina\u00e7\u00e3o de part\u00edculas.<br \/>\n<span style=\"line-height: 1.538em\">Classifica\u00e7\u00e3o dos filtros de ar<\/span><\/p>\n<table style=\"width: 100%;height: 372px\" border=\"0\" summary=\"Classifica\u00e7\u00e3o dos filtros de ar\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 165px\">\n<th style=\"height: 165px\" scope=\"col\">Grupo<\/th>\n<th style=\"height: 165px\" scope=\"col\">Classe<\/th>\n<th style=\"height: 165px\" scope=\"col\">Perda de carga finalPa<\/th>\n<th style=\"height: 165px\" scope=\"col\">Desempenho m\u00e9dio (<em>A<\/em>m) em compara\u00e7\u00e3o com o p\u00f3 sint\u00e9tico%<\/th>\n<th style=\"height: 165px\" scope=\"col\">Efici\u00eancia m\u00e9dia (<em>Em)<\/em> em compara\u00e7\u00e3o com part\u00edculas de 0,4 \u0272m%<\/th>\n<th style=\"height: 165px\" scope=\"col\">Efici\u00eancia m\u00ednima* em compara\u00e7\u00e3o com part\u00edculas de 0,4 \u0272m%<\/th>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"height: 92px\" rowspan=\"4\" valign=\"top\">Grosso<\/td>\n<td style=\"text-align: center;height: 23px\">G1<\/td>\n<td style=\"text-align: center;height: 23px\">250<\/td>\n<td style=\"text-align: center;height: 23px\">50 \u2264 <em>A<\/em>m &lt; 65<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"text-align: center;height: 23px\">G2<\/td>\n<td style=\"text-align: center;height: 23px\">250<\/td>\n<td style=\"text-align: center;height: 23px\">65 \u2264 <em>A<\/em>m &lt;80<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"text-align: center;height: 23px\">G3<\/td>\n<td style=\"text-align: center;height: 23px\">250<\/td>\n<td style=\"text-align: center;height: 23px\">80 \u2264 <em>A<\/em>m &lt;90<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"text-align: center;height: 23px\">G4<\/td>\n<td style=\"text-align: center;height: 23px\">250<\/td>\n<td style=\"text-align: center;height: 23px\">90 \u2264 <em>A<\/em>m<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"height: 46px\" rowspan=\"2\">M\u00e9dio<\/td>\n<td style=\"text-align: center;height: 23px\">M5<\/td>\n<td style=\"text-align: center;height: 23px\">450<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\">40 \u2264<em>E<\/em>m &lt; 60<\/td>\n<td style=\"height: 23px\"><\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"text-align: center;height: 23px\">M6<\/td>\n<td style=\"text-align: center;height: 23px\">450<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\">60 \u2264<em>E<\/em>m &lt;80<\/td>\n<td style=\"height: 23px\"><\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"height: 69px\" rowspan=\"3\">Fino<\/td>\n<td style=\"text-align: center;height: 23px\">F7<\/td>\n<td style=\"text-align: center;height: 23px\">450<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\">80 \u2264<em>E<\/em>m &lt;90<\/td>\n<td style=\"text-align: center;height: 23px\">35<\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"text-align: center;height: 23px\">F8<\/td>\n<td style=\"text-align: center;height: 23px\">450<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\">90 \u2264<em>E<\/em>m &lt;95<\/td>\n<td style=\"text-align: center;height: 23px\">55<\/td>\n<\/tr>\n<tr style=\"height: 23px\">\n<td style=\"text-align: center;height: 23px\">F9<\/td>\n<td style=\"text-align: center;height: 23px\">450<\/td>\n<td style=\"text-align: center;height: 23px\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;height: 23px\">95 \u2264<em>E<\/em>m<\/td>\n<td style=\"text-align: center;height: 23px\">70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 12px\">* A efici\u00eancia m\u00ednima \u00e9 o n\u00edvel de efici\u00eancia mais baixo entre a efici\u00eancia ap\u00f3s a descarga e a efici\u00eancia inicial, e a efici\u00eancia mais baixa ao longo de todo o processo da carga de teste.<\/span><\/p>\n<h2>Norma EN 779:2012 EUROVENT: 4\/21-2014<\/h2>\n<p>Classifica\u00e7\u00e3o energ\u00e9tica dos filtros<\/p>\n<table border=\"0\" width=\"1449\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th scope=\"col\" align=\"center\" width=\"17%\">Classe de filtro<\/th>\n<th scope=\"col\" align=\"center\" width=\"13%\">M5<\/th>\n<th scope=\"col\" align=\"center\" width=\"13%\">M6<\/th>\n<th scope=\"col\" align=\"center\" width=\"9%\">F7<\/th>\n<th scope=\"col\" align=\"center\" width=\"9%\">F8<\/th>\n<th scope=\"col\" align=\"center\" width=\"9%\">F9<\/th>\n<\/tr>\n<tr>\n<td align=\"center\">Efici\u00eancia inicial IPA 0,4 \u03bc<\/td>\n<td align=\"center\">n.a.<\/td>\n<td align=\"center\">n.a.<\/td>\n<td align=\"center\">\u00a0\u00a0\u00a0\u00a0 MTE <u>&gt;<\/u> 35%<\/td>\n<td align=\"center\">MTE <u>&gt;<\/u>\u00a055%<\/td>\n<td align=\"center\">MTE <u>&gt;<\/u>70%<\/td>\n<\/tr>\n<tr>\n<td align=\"center\">Classifica\u00e7\u00e3o energ\u00e9tica Eurovent<\/td>\n<td colspan=\"2\" align=\"center\">Consumo energ\u00e9tico ASHRAE poeira 250 g<\/td>\n<td colspan=\"3\" align=\"center\">Consumo energ\u00e9tico ASHRAE poeira 100 g<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;vertical-align: middle;background-color: #330099\"><strong style=\"color: #ffffff;font-size: 22px;line-height: 20.0063037872314px\">\u00a0 A+<\/strong><\/td>\n<td align=\"center\">0 &#8211; 450 kWh<\/td>\n<td align=\"center\">0 &#8211; 550 kWh<\/td>\n<td align=\"center\">0 &#8211; 800 kWh<\/td>\n<td align=\"center\">0 &#8211; 1000 kWh<\/td>\n<td align=\"center\">0 &#8211; 1250 kWh<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;background-color: #0000ff;vertical-align: middle\"><span style=\"font-size: 22px\"><span style=\"color: #ffffff\"><strong>A<\/strong><\/span><\/span><\/td>\n<td align=\"center\">&gt;450 &#8211; 600 kWh<\/td>\n<td align=\"center\">&gt;550 &#8211; 650 kWh<\/td>\n<td align=\"center\">&gt;800 &#8211; 950 kWh<\/td>\n<td align=\"center\">&gt;1000 -1200 kWh<\/td>\n<td align=\"center\">&gt;1250 &#8211; 1450 kWh<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;background-color: #00cc00\"><span style=\"color: #000000\"><span style=\"font-size: 22px\"><strong>B<\/strong><\/span><\/span><\/td>\n<td align=\"center\">&gt;600 &#8211; 700 kWh<\/td>\n<td align=\"center\">&gt;650 &#8211; 800 kWh<\/td>\n<td align=\"center\">&gt;950 &#8211; 1200 kWh<\/td>\n<td align=\"center\">&gt;1200 &#8211; 1500 kWh<\/td>\n<td align=\"center\">&gt;1450 &#8211; 1900 kWh<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;background-color: #ffff00\"><span style=\"color: #000000\"><span style=\"font-size: 22px\"><strong>C<\/strong><\/span><\/span><\/td>\n<td align=\"center\">&gt;700 &#8211; 950 kWh<\/td>\n<td align=\"center\">&gt;800 &#8211; 1100 kWh<\/td>\n<td align=\"center\">&gt; 1200 &#8211; 1700 kWh<\/td>\n<td align=\"center\">&gt;1500 &#8211; 2000 kWh<\/td>\n<td align=\"center\">&gt;1900 &#8211; 2600 kWh<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;background-color: #cc0000\"><span style=\"color: #000000\"><span style=\"font-size: 22px\"><strong>D<\/strong><\/span><\/span><\/td>\n<td align=\"center\">&gt;950 &#8211; 1220 kWh<\/td>\n<td align=\"center\">&gt;1100 &#8211; 1400 kWh<\/td>\n<td align=\"center\">&gt;1700 &#8211; 2200 kWh<\/td>\n<td align=\"center\">&gt;2000 &#8211; 3000 kWh<\/td>\n<td align=\"center\">&gt;2600 &#8211; 4000 kWh<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;background-color: #aa3f3c\"><span style=\"color: #000000\"><span style=\"font-size: 22px\"><strong>E <\/strong><\/span><\/span><\/td>\n<td align=\"center\">&gt;1200 kWh<\/td>\n<td align=\"center\">&gt;1400 \u00a0kWh<\/td>\n<td align=\"center\">&gt;2200 kWh<\/td>\n<td align=\"center\">&gt;3000 kWh<\/td>\n<td align=\"center\">&gt;4000 kWh<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Para obter mais informa\u00e7\u00f5es, consulte o website da EUROVENT : <a href=\"https:\/\/www.eurovent-certification.com\/es\/\">https:\/\/www.eurovent-certification.com\/es\/<\/a><\/p>\n<div id=\"dPathway\"><\/div>\n","protected":false},"featured_media":0,"template":"","tipo_normativa":[4447],"class_list":["post-40820","normativa","type-normativa","status-publish","hentry","tipo_normativa-especificacoes-de-filtros-industriais"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Norma EN779:2012 - Venfilter<\/title>\n<meta name=\"description\" content=\"Filtros de Ar de Ventila\u00e7\u00e3o Geral para a elimina\u00e7\u00e3o de part\u00edculas. Classifica\u00e7\u00e3o dos filtros de ar Grupo Classe Perda de carga finalPa Desempenho m\u00e9dio\" \/>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Norma EN779:2012 - Venfilter\" \/>\n<meta property=\"og:description\" content=\"Filtros de Ar de Ventila\u00e7\u00e3o Geral para a elimina\u00e7\u00e3o de part\u00edculas. Classifica\u00e7\u00e3o dos filtros de ar Grupo Classe Perda de carga finalPa Desempenho m\u00e9dio\" \/>\n<meta property=\"og:url\" content=\"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/\" \/>\n<meta property=\"og:site_name\" content=\"Venfilter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-20T09:00:27+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/\",\"url\":\"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/\",\"name\":\"Norma EN779:2012 - Venfilter\",\"isPartOf\":{\"@id\":\"https:\/\/venfilter.es\/pt-pt\/#website\"},\"datePublished\":\"2021-11-25T13:15:20+00:00\",\"dateModified\":\"2026-02-20T09:00:27+00:00\",\"description\":\"Filtros de Ar de Ventila\u00e7\u00e3o Geral para a elimina\u00e7\u00e3o de part\u00edculas. Classifica\u00e7\u00e3o dos filtros de ar Grupo Classe Perda de carga finalPa Desempenho m\u00e9dio\",\"breadcrumb\":{\"@id\":\"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/venfilter.es\/pt-pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Norma EN779:2012\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/venfilter.es\/pt-pt\/#website\",\"url\":\"https:\/\/venfilter.es\/pt-pt\/\",\"name\":\"Venfilter\",\"description\":\"Filtros de aire y ventilaci\u00f3n industrial\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/venfilter.es\/pt-pt\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Norma EN779:2012 - Venfilter","description":"Filtros de Ar de Ventila\u00e7\u00e3o Geral para a elimina\u00e7\u00e3o de part\u00edculas. Classifica\u00e7\u00e3o dos filtros de ar Grupo Classe Perda de carga finalPa Desempenho m\u00e9dio","robots":{"index":"noindex","follow":"follow"},"og_locale":"pt_PT","og_type":"article","og_title":"Norma EN779:2012 - Venfilter","og_description":"Filtros de Ar de Ventila\u00e7\u00e3o Geral para a elimina\u00e7\u00e3o de part\u00edculas. Classifica\u00e7\u00e3o dos filtros de ar Grupo Classe Perda de carga finalPa Desempenho m\u00e9dio","og_url":"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/","og_site_name":"Venfilter","article_modified_time":"2026-02-20T09:00:27+00:00","twitter_card":"summary_large_image","twitter_misc":{"Tempo estimado de leitura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/","url":"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/","name":"Norma EN779:2012 - Venfilter","isPartOf":{"@id":"https:\/\/venfilter.es\/pt-pt\/#website"},"datePublished":"2021-11-25T13:15:20+00:00","dateModified":"2026-02-20T09:00:27+00:00","description":"Filtros de Ar de Ventila\u00e7\u00e3o Geral para a elimina\u00e7\u00e3o de part\u00edculas. Classifica\u00e7\u00e3o dos filtros de ar Grupo Classe Perda de carga finalPa Desempenho m\u00e9dio","breadcrumb":{"@id":"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/venfilter.es\/pt-pt\/normativa\/norma-en7792012\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/venfilter.es\/pt-pt\/"},{"@type":"ListItem","position":2,"name":"Norma EN779:2012"}]},{"@type":"WebSite","@id":"https:\/\/venfilter.es\/pt-pt\/#website","url":"https:\/\/venfilter.es\/pt-pt\/","name":"Venfilter","description":"Filtros de aire y ventilaci\u00f3n industrial","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/venfilter.es\/pt-pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"}]}},"_links":{"self":[{"href":"https:\/\/venfilter.es\/pt-pt\/wp-json\/wp\/v2\/normativa\/40820","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/venfilter.es\/pt-pt\/wp-json\/wp\/v2\/normativa"}],"about":[{"href":"https:\/\/venfilter.es\/pt-pt\/wp-json\/wp\/v2\/types\/normativa"}],"wp:attachment":[{"href":"https:\/\/venfilter.es\/pt-pt\/wp-json\/wp\/v2\/media?parent=40820"}],"wp:term":[{"taxonomy":"tipo_normativa","embeddable":true,"href":"https:\/\/venfilter.es\/pt-pt\/wp-json\/wp\/v2\/tipo_normativa?post=40820"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}